2026-11-04
Under-hood connectors sit in one of the least forgiving sealing environments in a vehicle. The seal works a few centimetres from a heat source cycling between ambient and well over 150 °C, it is washed in oil vapour and fuel permeation, and it is clamped between two moulded housings whose grooves were designed before the seal was specified.
This case looks at an under-hood wiring harness connector program originally specified with a standard NBR O-ring at 70 Shore A. New parts passed bench leak tests. Field trials came back with two symptoms: a slow weep at the connector interface after sustained high-temperature running, and a permanent set that made re-mating hard on the assembly line.
Only the first looks like a temperature problem. The field failures were driven by the second and third, which is why a higher temperature rating alone did not stop the leak.
| Material | Continuous heat | Oil / fuel vapour | Low-temp flex | Verdict |
|---|---|---|---|---|
| NBR 70 | Moderate | Good on mineral oil | Good | Failed on compression set |
| HNBR 70 | High | Very good, incl. fuel vapour | Good | Selected |
| FKM 70 | Very high | Excellent | Limited | Rejected: cold re-mating force |
| VMQ 70 | Very high | Poor in oil | Excellent | Rejected: oil vapour swell |
HNBR was the only candidate holding all three requirements at once: heat ageing close to FKM, oil and fuel vapour resistance better than NBR, and enough cold flexibility for winter assembly. Hardness stayed at 70 Shore A, so groove fill did not change.
For a validation program that needs five sizes at low volume, that structure removes the usual barrier: no mould investment has to be justified before the seal proves itself in a heat cycle.
HNBR at the same hardness and the same groove dimensions addressed both field symptoms without touching the housing design. Re-mating force came back inside the target band, and the weep at the connector interface stopped appearing after sustained high-temperature running.
The transferable lesson: specify against the failure mode, not against the temperature rating. A seal rated for the heat but taking a permanent set in a shallow groove will still leak; a seal that resists oil but hardens in the cold will still stop your line.
Send the groove drawing, media list, service temperature range and target hardness. We will tell you which candidate fits, whether the size is already in mould, and what the per-size minimum looks like — usually within eight working hours. If we cannot make your size, we will say so in the same eight hours instead of leaving you waiting.
Ask for the size list too. Our published list covers more than 5,400 sizes, but it is never the whole story — we open new moulds every month.